Enquire Now

Olympus live cell imaging and screening station

MANUFACTURER Olympus
MODEL Cell^R/Scan^R system
AVAILABILITY By appointment or online booking
TRAINING Training is required to use this item and we can arrange this if needed.
CONTACT 1 Dr Kees Straatman (HWB) x7085/2263
Enquire about this item

Description

Please visit http://www2.le.ac.uk/colleges/medbiopsych/facilities-and-services/cbs/lite/aif/Equipment/microscopes/cell-r-scan-r-system

This microscope is an inverted IX81 motorized microscope which combines the Scan^R screening platform and Cell^R imaging station in one system. The Scan^R screening platform can be used for assay development and high-content screening using multiwell plates as well as single slides. This makes it possible to screen both large and small numbers of samples. It has fully automated image acquisition which allows the user to select the number of images per well, the number of wells and the different filter sets. Many brands of multiwell plates are preprogrammed. Results can be analyzed with the powerful image analysis software for automated object detection and cell separation using histograms and gating settings to include or exclude data sets. For live cell imaging as well as for imaging of fixed materials the Cell^R option can be used. This allows fast acquisition and multiple position imaging for many hours. Protocols can be written in the Cell^R software to do complicated image and filter sequences.

This system is equipped with a Hamamatsu ORCA-AG CCD camera (pixel size 6.45x6.45 ┬Ám), DIC objectives, hardware ZDC (Zero Drift Compensation) and software autofocus, linear encoders for high xy-precision, CO2 and a stage incubator for live imaging.

In June 2013 we updated the CellR software to the new Xcellence software, version 1.2. This software replaces the CellR software but has basically the same look and feel. The ScanR Acquisition and ScanR analysis software have been updated to version 2.4.0.13 for Acquisition and 2.4.0.11 for Analysis.

Filter wheel with excitation filters for: DAPI (350/50) FITC (492/18) TxRed (572/23) CFP (430/25) GFP(470/22) YFP (500/20) mRFP (556/20) Cy5 (640/30).

Emission filter cubes on the microscope: DAPI/FITC/TRITC (U-61002bs, U-61002m) CFP/YFP GFP/RFP (U-51019x, U-51019bs, U-51019m) HqFITC (Dichroic 505LP, emission 535/50) Cy5 (Dichroic 660LP, emission 700/75m)

We have a second licence for both the Scan^R analysis software and the Cell^R software to analyze data on the analysis computers in room G1a.

Item ID #921.

Last Updated: 6th June, 2014

Olympus live cell imaging and screening station